UPS
Servo Voltage Stabilizer
Inverters
Batteries
Other Branded UPS
Other Branded Inverters
Power Factor Controller
Constant Voltage Transformers
|

|
Long Backup UPS
Features :
- Micro-controller based design
- Selectable battery option
- Runs single PC up to 15.0 hrs with 24V 150 AH battery
- Charges battery very fast
- Pre-loaded battery management software
- Regulated output voltage window during regulated UPS mode
- Regulated battery charging from 120V to 300V
- Automatic holiday mode preserves battery charge(away from home for long time)
- Audio alarms on : mains fail, charger blown, battery low, no load shutdown
- Visual indications on : mains on, UPS on, smart charge, overload / short circuit trip, charger fuse blown, battery low, no load shutdown
|
|
| TECHNICAL SPECIFICATIONS |
| INPUT |
RATING |
600VA |
800VA |
1400VA |
|
Regulated UPS Mode |
| Under voltage | 180+/-5V |
| Over voltage | 265+/-5V |
| Unregulated UPS Mode |
| Under voltage | 100+/-10V |
| Over voltage | 300+/-10V |
| BATTERY |
Type | 120AH - 150AH Lead Acid Type |
| Number | 1 | 1 | 2 |
|
|
FEATURES OF LUMINOUS INVERTERS
Regenerative Energy Cycling - Technology
- Advanced Energy Flow Management for lowest electricity consumption.
- Reduced Component-Stress for more reliability & longer service life.
- Harmonics Compensated Wave shape for higher appliance life.
|
 |
SMARTcharge-Technology
- Charges batteries two times faster.
- Advanced Battery Management: enhances battery life by up to 70%.
- Negligible battery water loss.
- Intelligent continuous charging profile adjustment.
|
OTHER UNIQUE FEATURES OF LUMINOUS INVERTER
- Electronic overload/Short-circuit protection.
- Battery deep discharge protection.
- Battery undercharge/overcharge protection.
- Battery reverse polarity protection.
- Battery charging even at sustained Mains Low voltage up to 160V.
|
Specifications
|
RATING | 600VA | 800VA | 1400VA | 2000VA |
| Frequency | Same as input |
| INVERTER MODE | 50HZ +/-2% |
| OUTPUT VOLTAGE | SAME AS INPUT VOLTAGE |
| INVERTER MODE | 220V AC NOMINAL |
| OUTPUT WAVE FORM | QUASI SINE WAVE |
| MAXIMUM CAPACITY |
| INVERTER MODE | 600VA | 800VA | 1400VA | 2000VA |
| MAINS MODE | 2.5KVA | 2.5KVA | 2.5KVA | 2.5KVA |
| DC INPUT | 12 V | 12 V | 24V | 48V |
| CHARGING CURRENT | 5.6 Amp | 7.8 Amp | 8.9 Amp | 10Amp |
| CHANGEOVER TIME | 70 ms |
| ENVIRONMENT |
| OPERATING TEMP | 0 TO 40 deg C |
| STORAGE TEMP | 0 TO 45 deg C |
| HUMIDITY | 0 TO 95% (NON CONDENSING) |
| INDICATIONS | Mains ON, Inv. ON, Battery charging, Battery |
| | low trip, Over load trip, Battery & load |
| level bar graph |
| PROTECTIONS | Electronic over load/short circuit protection, |
| Battery deep discharge protection, Battery |
| Reverse polarity protection,Battery over/under |
| Charge protection, MCB at out put |
| BATTERY CHARGING | 140V AC TO 270V AC |
| VOLTAGE RANGE | |
| DIMENSION |
| W x L x H IN MM | 397 x 355 x 120 | 397 x 385 x 156 | 510 x 580 x 260 |
| TROLLEY ( FEET) | 1.5 x 1.5 x 1.5 | 2 x 2 x 2 | 2 x 2 x 2 |
| NET WEIGHT(kgs.) | 13 | 15 | 24 | 28.5 |
| |
|